- All Products
- Single-Gas Detectors
- Multi-Gas Detectors
- Maintenance Free
- BW Clip
- BW Solo
- BW Clip4
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- BW Ultra
- IntelliDox
- Calibration Equipment
- Replacement Sensors
- SR-X2V Replacement Oxygen (O2) Sensor
- SR-X10 Replacement Oxygen (O2) Sensor
- SR-X10-C1 Replacement Oxygen (O2) Sensor (for use with GAXT-X-DL-2 and GAXT-X-DL-B-2 models)
- SR-W-MP75C Replacement MICROpeL Combustible (LEL) Sensor
- SR-H-MC Replacement MICROceL Hydrogen Sulfide (H2S) Sensor
- SR-M-MC Replacement MICROceL Carbon Monoxide (CO) Sensor
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- PS-RH04S Replacement Hydrogen Sulfide (H2S) Sensor
- SR-M04-SC Replacement Carbon Monoxide (CO) Sensor
- PS-RM04H Replacement Carbon Monoxide (CO) Sensor, H2 Resistant
- PS-RS04 Replacement Sulfur Dioxide (SO2) Sensor
- PS-RC10 Replacement Chlorine (Cl2) Sensor
- PS-RZ10 Replacement Hydrogen Cyanide (HCN) Sensor
- SR-N04 Replacement Nitric Oxide (NO) Sensor
- PS-RD04 Replacement Nitrogen Dioxide (NO2) Sensor
- SR-A04 Replacement Ammonia (NH3) Sensor
- SR-A204 Replacement Ammonia (NH3) Sensor, Extended Range
- SR-P04 Replacement Phosphine (PH3) Sensor
- SR-G04 Replacement Ozone (O3) Sensor
- SR-E04 Replacement Ethylene Oxide (ETO) Sensor
- SR-V04 Replacement Chlorine Dioxide (ClO2) Sensor
- SR-DUMM3 Dummy Sensor for PID Location
- SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location
- SR-DUMM1 Dummy Sensor for the Oxygen Sensor Location
- SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations
- SR-W04-75C Replacement Combustible (LEL) Sensor
- SR-H04-SC Replacement Hydrogen Sulfide (H2S) Sensor
- SR-DUMM2 Dummy Sensor for the Combustible (LEL) Location
- SR-B04 Replacement Carbon Dioxide (CO2) IR Sensor
- SR-Q07 Replacement Volatile Organic Compounds (VOC) PID Sensor, 10.6 eV
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- SR-W04 Replacement Combustible Sensor with Heavy Duty Silicone Filter
- SR-W04-UF Replacement Combustible Sensor without Heavy Duty Silicone Filter
- SR-ER04 Replacement Ethylene Oxide (ETO) Sensor (4-Series)
- SR-H1-1S Replacement Hydrogen Sulfide (H2S) Sensor (one-series)
- SR-M1-1S Replacement Carbon Monoxide (CO) Sensor (one-series)
- SR-NR04 Replacement Nitric Oxide (NO) Sensor (4-Series)
- SR-RR04 Replacement Hydrogen (H2) Sensor (4-Series)
- SR-W04-75 Replacement Combustible (LEL) Sensor, for GasAlertQuattro (Unfiltered)
- SR-X1-1S Replacement Oxygen (O2) Sensor (one-series)
- SR-ZR04 Replacement Hydrogen Cyanide (HCN) Sensor (4-Series)
- SR-X-MC Replacement MICROceL Oxygen (O2) Sensor
- Confined Space Kits
- MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit
- MC-CK-CC Carrying Case for GasAlertMicroClip - with Foam and Lid Insert
- QT-XWHM-R-Y-NA-CS GasAlertQuattro Confined Space Kit
- QT-CK-DL GasAlertQuattro Deluxe Confined Space Kit
- QT-CK-CC Carrying Case for GasAlertQuattro with Foam Insert
- XT-XWHM-Y-NA-CS GasAlertMax XT II Confined Space Kit
- XT-CK-DL GasAlertMax XT II Deluxe Confined Space Kit
- XT-CK-CC Carrying Case for GasAlertMax XT - with foam insert from XT-CK-DL kit
- M5-CK-DL GasAlertMicro 5 Series Deluxe Confined Space Kit
- M5-CK-CC Carrying Case for GasAlertMicro 5 Series - with Foam and Lid Insert from M5-CK-DL Kit
- HU-CK-DL BW™ Ultra Deluxe Confined Space Kit
- HU-CK-CC Carrying Case for Honeywell BW™ Ultra with Foam and Lid Insert
- QT-XUHM-R-Y-NA-CS GasAlertQuattro Premium Confined Space Kit
- XT-XUHM-Y-NA-CS GasAlertMax XT II Premium Confined Space Kit
- Other BW Products
HRR-B30059CK00-000 BW RigRat Portable Gas Monitor with 4 gas sensors only (LEL, H2S, and CO2 & O2)
Item #:
HRR-B30059CK00-000
Brand:
BW Technologies
Share this product:
Honeywell BW™ RigRat is so easy to use that workers can operate it with confidence, trusting it to alert them to gas threats in their proximity — indoors and out, in temperatures from -40 to +140°F (-40 to +60°C). Honeywell BW™ RigRat delivers:
- Up to 8 weeks of runtime on a single charge. Longer runtime than any area monitor in its class.
- Up to six slots for interchangeable gas sensors. Choice of electrochemical, PID, infrared, and catalytic bead sensors (measuring percent LEL and percent by volume).
- Integrated Noise sensor and Metrological data sensors.
- Enhanced configurations with programmable input and output.
- Approval for explosive atmosphere. Certified for ATEX/IECEx Zone 0 and CSA C1D1.
- Flexible applications. Zone declassification, turnarounds, confined space, routine maintenance, fence line and more. Available with pump for remote sampling.
- One-button operation. Grab and go. No expertise required.
- Simple setup with a smartphone. Easy mobile app for alarm set points, calibration records and more.
- Added protection. Alerts workers to nearby gas leaks, whereas personal detectors cover only the breathing zone.
FEATURES AND BENEFITS
- WIRELESS SAFETY PERIMETER: Position several Honeywell BW™ RigRat monitors to form a wireless safety perimeter.
- REMOTE MONITORING: Use with Honeywell's remote monitoring software to see gas readings, location and other data from any device with an internet connection — for fast, informed decisions. Add an optional noise sensor or meteorological sensor.
- HONEYWELL TOUCHPOINT™ PLUS COMPATIBLE: Use with the Honeywell Touchpoint™ Plus controller for visibility on Honeywell BW™ RigRat monitors and workers' personal detectors.
OTHER HONEYWELL BWTM RIGRAT FEATURES:
- Line power for extended runtime in the field
- I/O ports providing additional input capabilities and local executive activation.
- Inert mode that prevents alarm in normal ambient air.
- Large, easy-to-read display
- Rugged, weatherproof design, with optional protective cage
INSTRUMENT SPECIFICATIONS (TYPICAL) | |||
MODEL NUMBER | BWRR100P/BWRR100D | ||
SIZE | 15.8 x 11.4 x 18.5 in. / 40.0 x 29.0 x 47.0 cm | ||
WEIGHT | 17.6 lb / 8 kg | ||
GAS SENSOR SLOTS | Up to 6 | ||
GAS SAMPLING METHOD | Pumped or diffusion | ||
BATTERY | Rechargeable Li-ion battery (3.7V / 26.4 Ah) | ||
CHARGING TIME | Less than 18 hours when instrument is powered off | ||
RUNNING TIME | 8 weeks for low-power model; other models vary by configuration | ||
KEYPADS | One-button operation and programing | ||
DISPLAY | 3.5" 240 x 320 TFT color LCD with white LED backlight | ||
ALARM | Red/yellow/green LED alarm; buzzer alarm 108 dBA @ 1 m; on-screen indication of alarm conditions | ||
DATALOGGING | Complete gas sensors and instrument information for at least 4 months at one minute intervals | ||
WIRELESS | ISM license free band: Bluetooth Low Energy Module (BT 4.2 / 5.0), 2.4 GHz, in default; Mesh Module: IEEE 802.15.4 868 MHz / 915MHz /2.4 GHz (optional); OR Wi-Fi Module: 802.11 b/g/n 2.4 GHz (optional) |
||
RADIO MODULE & RANGE | Bluetooth Low Energy: RMBLEC, up to 16.4 ft. / 5 m; Mesh: RM900A, 984 ft. / 300 m (868-900 MHz) or RM2400, 492 ft. / 150 m (2.4 GHz ); Wi-Fi: RMWIFIC, up to 164 ft. / 50 m; |
||
OUTDOOR LOCATION | GPS receiver module: GPS L1 frequency (1575.42 MHz) (optional); Only with IEEE 802.15.4 868 MHz / 915MHz modem and WIFI |
||
IP RATING | IP65 for pumped models; IP67 for diffusion models | ||
TEMPERATURE | -4 to +140°F (-20 to +60°C) for pumped models; -40 to +140°F (-40 to +60°C) for diffusion models |
||
HUMIDITY | 5 - 95% RH (non-condensing) | ||
SAFETY CERTIFICATIONS (PENDING) | cETLus Class I Division 1; Group A, B, C, D; T4; IEC EX/ATEX I M1 Ex ia I Ma II 1G Ex ia da IIC T4 Ga For LELIR/CO2 sensor installed: I M1 Ex ia I Ma II 2G Ex ia da db IIC T4 Gb 1G Ex ia da IIC T4 Ga |
||
WIRELESS APPROVALS (PENDING) | FCC Part 15, IC, RE-D | ||
ROHS (PENDING) | RoHS Complaint, Directive (EU) 2015/863 | ||
NOISE SENOR | 60-125 dBA range; (respond: 100 Hz to 8 kHz), 1 dB resolution; A-weighted 15 second equivalent level; updated every 5 seconds |
||
EXTERNAL PORTS | |||
SAFE AREA CHARGE PORT (AC CHG SAFE AREA) | Battery charger input 6 VDC 3 A typical; connect to AC/DC adaptor | ||
FIELD CHARGE (IS CHG HAZARDOUS) | Intrinsically safe line power supply input to extend instrument runtime (low-power model only) | ||
RAEMET PORT (SERIAL) | Port to RAEMet wind sensor (optional) | ||
ANALOG/SWITCH INPUT PORT (4-20 MA IN) | 4-20 mA signal input, X1 channel/switch on/off signal input, X1 channel (optional) | ||
ON/OFF SWITCH OUTPUT (SWITCH) | Max 20 V / 120 mA, SPDT Normal Open, X3 channels for external ports (optional). Refer to User Guide for complete details. | ||
SENSOR SPECIFICATIONS | |||
SENSOR | RANGE |
RESOLUTION |
TEMPERATURE RANGE |
COMBUSTIBLE GASES (IR)* | 0-100% LEL / 0-100% vol. |
1% LEL / 0.1% vol. |
-40 to +140° F / -40 to +60° C |
COMBUSTIBLE GASES (LEL) | 0-100% LEL |
1% LEL |
-40 to +140° F / -40 to +60° C |
CARBON DIOXIDE (CO2) | 0-5% vol. / 100 ppm |
0.01% vol. / 100 ppm |
-4 to +131° F / -20 to +50° C |
CARBON DIOXIDE (CO2) (EXT. RANGE) | 0-100% vol. |
0.1% vol. |
-4 to +131° F / -20 to +50° C |
VOLATILE ORGANIC COMPOUNDS (VOC) | 0-2000 ppm |
0.1 ppm |
-4 to +131° F / -20 to +50° C |
CARBON MONOXIDE (CO) | 0-500 ppm |
1 ppm |
-40 to +140° F / -40 to +60° C |
CARBON MONOXIDE (CO) (EXT. RANGE) | 0-2000 ppm |
10 ppm |
-4 to +131° F / -20 to +50° C |
CARBON MONOXIDE (CO) (H2 RESISTANT) | 0-1000 ppm |
5 ppm |
-4 to +140° F / -20 to +60° C |
HYDROGEN SUFLIDE (H2S) | 0-100 ppm |
0.1 ppm |
-40 to +140° F / -40 to +60° C |
HYDROGEN SUFLIDE (H2S) (EXT. RANGE) | 0-1000 ppm |
1 ppm |
-4 to +131° F / -20 to +50° C |
SULFUR DIOXIDE (SO2) | 0-20 ppm |
0.1 ppm |
-40 to +140° F / -40 to +60° C |
OXYGEN (O2) | 0-30% vol. |
0.1% vol. |
-40 to +140° F / -40 to +60° C |
NITRIC OXIDE (NO) | 0-250 ppm |
0.5 ppm |
-4 to +131° F / -20 to +50° C |
NITROGEN DIOXIDE (NO2) | 0-20 ppm |
0.1 ppm |
-4 to +131° F / -20 to +50° C |
HYDROGEN CYANIDE (HCN) | 0-50 ppm |
0.5 ppm |
-4 to +131° F / -20 to +50° C |
AMMONIA (NH3) | 0-100 ppm |
1 ppm |
-4 to +131° F / -20 to +50° C |
CHLORINE (CL2) | 0-50 ppm |
0.1 ppm |
-4 to +131° F / -20 to +50° C |
*Note: Temperature range for the Dynament Combustible IR sensor is -4 to +131°F (-20 to +50°C). |