- All Products
- Single-Gas Detectors
- Multi-Gas Detectors
- Maintenance Free
- BW Clip
- BW Solo
- BW Clip4
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- BW Ultra
- IntelliDox
- Calibration Equipment
- Replacement Sensors
- SR-X2V Replacement Oxygen (O2) Sensor
- SR-X10 Replacement Oxygen (O2) Sensor
- SR-X10-C1 Replacement Oxygen (O2) Sensor (for use with GAXT-X-DL-2 and GAXT-X-DL-B-2 models)
- SR-W-MP75C Replacement MICROpeL Combustible (LEL) Sensor
- SR-H-MC Replacement MICROceL Hydrogen Sulfide (H2S) Sensor
- SR-M-MC Replacement MICROceL Carbon Monoxide (CO) Sensor
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- PS-RH04S Replacement Hydrogen Sulfide (H2S) Sensor
- SR-M04-SC Replacement Carbon Monoxide (CO) Sensor
- PS-RM04H Replacement Carbon Monoxide (CO) Sensor, H2 Resistant
- PS-RS04 Replacement Sulfur Dioxide (SO2) Sensor
- PS-RC10 Replacement Chlorine (Cl2) Sensor
- PS-RZ10 Replacement Hydrogen Cyanide (HCN) Sensor
- SR-N04 Replacement Nitric Oxide (NO) Sensor
- PS-RD04 Replacement Nitrogen Dioxide (NO2) Sensor
- SR-A04 Replacement Ammonia (NH3) Sensor
- SR-A204 Replacement Ammonia (NH3) Sensor, Extended Range
- SR-P04 Replacement Phosphine (PH3) Sensor
- SR-G04 Replacement Ozone (O3) Sensor
- SR-E04 Replacement Ethylene Oxide (ETO) Sensor
- SR-V04 Replacement Chlorine Dioxide (ClO2) Sensor
- SR-DUMM3 Dummy Sensor for PID Location
- SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location
- SR-DUMM1 Dummy Sensor for the Oxygen Sensor Location
- SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations
- SR-W04-75C Replacement Combustible (LEL) Sensor
- SR-H04-SC Replacement Hydrogen Sulfide (H2S) Sensor
- SR-DUMM2 Dummy Sensor for the Combustible (LEL) Location
- SR-B04 Replacement Carbon Dioxide (CO2) IR Sensor
- SR-Q07 Replacement Volatile Organic Compounds (VOC) PID Sensor, 10.6 eV
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- SR-W04 Replacement Combustible Sensor with Heavy Duty Silicone Filter
- SR-W04-UF Replacement Combustible Sensor without Heavy Duty Silicone Filter
- SR-ER04 Replacement Ethylene Oxide (ETO) Sensor (4-Series)
- SR-H1-1S Replacement Hydrogen Sulfide (H2S) Sensor (one-series)
- SR-M1-1S Replacement Carbon Monoxide (CO) Sensor (one-series)
- SR-NR04 Replacement Nitric Oxide (NO) Sensor (4-Series)
- SR-RR04 Replacement Hydrogen (H2) Sensor (4-Series)
- SR-W04-75 Replacement Combustible (LEL) Sensor, for GasAlertQuattro (Unfiltered)
- SR-X1-1S Replacement Oxygen (O2) Sensor (one-series)
- SR-ZR04 Replacement Hydrogen Cyanide (HCN) Sensor (4-Series)
- SR-X-MC Replacement MICROceL Oxygen (O2) Sensor
- Confined Space Kits
- MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit
- MC-CK-CC Carrying Case for GasAlertMicroClip - with Foam and Lid Insert
- QT-XWHM-R-Y-NA-CS GasAlertQuattro Confined Space Kit
- QT-CK-DL GasAlertQuattro Deluxe Confined Space Kit
- QT-CK-CC Carrying Case for GasAlertQuattro with Foam Insert
- XT-XWHM-Y-NA-CS GasAlertMax XT II Confined Space Kit
- XT-CK-DL GasAlertMax XT II Deluxe Confined Space Kit
- XT-CK-CC Carrying Case for GasAlertMax XT - with foam insert from XT-CK-DL kit
- M5-CK-DL GasAlertMicro 5 Series Deluxe Confined Space Kit
- M5-CK-CC Carrying Case for GasAlertMicro 5 Series - with Foam and Lid Insert from M5-CK-DL Kit
- HU-CK-DL BW™ Ultra Deluxe Confined Space Kit
- HU-CK-CC Carrying Case for Honeywell BW™ Ultra with Foam and Lid Insert
- QT-XUHM-R-Y-NA-CS GasAlertQuattro Premium Confined Space Kit
- XT-XUHM-Y-NA-CS GasAlertMax XT II Premium Confined Space Kit
- Other BW Products
BWC4-B-N BW Clip4 4-Gas Detector (O2, LEL, H2S, CO), North American version - Black Housing
Item #:
BWC4-B-N
Brand:
BW Technologies
Share this product:
BW Clip4 - Continual Multi Gas Protection
"Always on" technology with Honeywell safety and dependability
When you're fully occupied on the job, the last thing you need is hassles with your gas protection system. Why worry about charging the gas detector, checking the battery, or replacing sensors when you don't have to? The BW Clip4 is designed for simplicity, ease of use, and cost-effective ownership. It's one less thing to worry about. As you go through your busy day, you receive constant protection from Honeywell's supporting technology and quality.
Runs Continuously for Two Full Years
It's as easy as activating and clipping it on. Never charge it up or think about the battery for 24 months.YOU GET THESE GREAT FEATURES AND BENEFITS
Wearing the BW Clip4
- Comfortable, ergonomic and durable
- Small profile - in tight spaces, it's unnoticeable
Using BW Clip4
- Single-button operation
- User-friendly and virtually tamper-proof operation
- Intuitive LCD icon technology shows you real-time gas readings
BW Clip4 Compliance
- Non-compliance indicators let you know the unit hasn't been bump tested on schedule
- Battery, sensors, circuit integrity, and visual/audible alarms automatically tested daily
BW Clip4 Management
- IntelliDoX docking simplifies data management
BW Clip4 Durability
- Boot is concussion-proof
- Tested under harsh conditions
BW Clip4 Technical Specifications
- TYPICAL BATTERY LIFE Two years, continuous operation
- EVENT LOGGING 70 of your most recent events
- OPERATING TEMPERATURE -20 to +50°C (-4 to +131°F)
- HUMIDITY 5 - 95% RH (non-condensing) continuous
- SIZE 4.7 x 2.7 x 1.3 in. / 12.0 x 6.8 x 3.2 cm
- WEIGHT 8.2 oz. / 233 grams
- INGRESS PROTECTION rated at IP68
- ALARMS Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit)
- SELF-TEST Activated detectors automatically do one internal diagnostic test every day/24 hours (sensors, battery, and circuitry).
BW Clip4 Options
- Set STEL for 1 min intervals (from 5 to 15 minutes)
- Calibration span levels
- Calibration interval setting
- Bump test interval setting
- Stealth mode
- Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v
- Calibration due date from 1 to 365 days (or zero for off)
- Individual sensor control
- Latching alarms
APPROVALS AND CERTIFICATIONS:
- Class I, Div 1, Group A, B, C, D
- Class I, Zone 0, Group IIC
- ATEX: II 1G Ex ia IIC T4 Ga
- IECEx: Ex ia IIC T4 Ga
- X: Conforms to all (applicable) European directives.
- For more certifications, please check manual or consult Honeywell Analytics.
WARRANTY Full two-years (includes battery & sensors)
GASES | STANDARD MEASURING RANGE |
RESOLUTION |
HYDROGEN SULFIDE (H2S) | 0 - 100 ppm |
1 / 0.1 ppm |
CARBON MONOXIDE (CO) | 0 - 1,000 ppm |
1 ppm |
OXYGEN (O2) | 0 - 25% vol. |
0.1% vol. |
COMBUSTIBLE GASES (LEL)* | 0 - 100% LEL |
1% LEL |
*Caution - The BW Clip4 cannot sense all combustible gases (like acetylene and hydrogen). Before using, make sure your detector meets all your specifications for protection. |
The Power of IntelliDoX
When you use IntelliDox with Honeywell instrument management systems, you enjoy the power of automated data storage and testing. Using IntelliDox is easy. Just put the BW Clip4 in the dock to quickly test sensors and unit. Data transfer is quick and easy (to any computer) for compliance tracking, configuration and analysis.
COLOR OPTIONS
Choose Honeywell signature black or highly visible yellow
SIZE | 4.7 x 2.7 x 1.3 in. / 12.0 x 6.8 x 3.2 cm |
WEIGHT | 8.2 oz. / 233 g |
OPERATING TEMPERATURE | -4 to +131°F / -20 to +50°C |
HUMIDITY | 5 - 95% RH (non‑condensing) continuous |
INGRESS PROTECTION | IP68 |
ALARMS AND TYPE | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit) |
SELF-TEST | Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry). |
TYPICAL BATTERY LIFE | Two years, continous operation |
EVENT LOGGING | 70 most recent events |
USER OPTIONS | # Adjust STEL period (5-15 minutes in 1 minute intervals) # Calibration span levels # Calibration interval # Bump test interval # Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v # Calibration due date (1 to 365 days, or set to zero for off) # Individual sensor enable/disable # Latching alarms # Stealth mode |
WARRANTY | Full two-year warranty including sensors and battery |
GASES | STANDARD MEASURING RANGE |
RESOLUTION |
HYDROGEN SULFIDE (H2S) | 0 - 100 ppm |
1 / 0.1 ppm |
CARBON MONOXIDE (CO) | 0 - 1,000 ppm |
1 ppm |
OXYGEN (O2) | 0 - 25% vol. |
0.1% vol. |
COMBUSTIBLE GASES (LEL)* | 0 - 100% LEL |
1% LEL |
* Caution - the LED IR combustible gas sensor used in BW Clip4 cannot detect certain combustible gases including hydrogen and acetylene. The application should be reviewed to ensure the BW Clip4 can provide adequate detection. For more information, please contact Honeywell Analytics (www.honeywellanalytics.com). |