- All Products
- Single-Gas Detectors
- Multi-Gas Detectors
- Maintenance Free
- BW Clip
- BW Solo
- BW Clip4
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- BW Ultra
- IntelliDox
- Calibration Equipment
- Replacement Sensors
- SR-X2V Replacement Oxygen (O2) Sensor
- SR-X10 Replacement Oxygen (O2) Sensor
- SR-X10-C1 Replacement Oxygen (O2) Sensor (for use with GAXT-X-DL-2 and GAXT-X-DL-B-2 models)
- SR-W-MP75C Replacement MICROpeL Combustible (LEL) Sensor
- SR-H-MC Replacement MICROceL Hydrogen Sulfide (H2S) Sensor
- SR-M-MC Replacement MICROceL Carbon Monoxide (CO) Sensor
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- PS-RH04S Replacement Hydrogen Sulfide (H2S) Sensor
- SR-M04-SC Replacement Carbon Monoxide (CO) Sensor
- PS-RM04H Replacement Carbon Monoxide (CO) Sensor, H2 Resistant
- PS-RS04 Replacement Sulfur Dioxide (SO2) Sensor
- PS-RC10 Replacement Chlorine (Cl2) Sensor
- PS-RZ10 Replacement Hydrogen Cyanide (HCN) Sensor
- SR-N04 Replacement Nitric Oxide (NO) Sensor
- PS-RD04 Replacement Nitrogen Dioxide (NO2) Sensor
- SR-A04 Replacement Ammonia (NH3) Sensor
- SR-A204 Replacement Ammonia (NH3) Sensor, Extended Range
- SR-P04 Replacement Phosphine (PH3) Sensor
- SR-G04 Replacement Ozone (O3) Sensor
- SR-E04 Replacement Ethylene Oxide (ETO) Sensor
- SR-V04 Replacement Chlorine Dioxide (ClO2) Sensor
- SR-DUMM3 Dummy Sensor for PID Location
- SR-W-MC-DUM Dummy Sensor for Combustible Sensor Location
- SR-DUMM1 Dummy Sensor for the Oxygen Sensor Location
- SR-TOX-MC-DUM Dummy Sensor for Toxic Sensor Locations
- SR-W04-75C Replacement Combustible (LEL) Sensor
- SR-H04-SC Replacement Hydrogen Sulfide (H2S) Sensor
- SR-DUMM2 Dummy Sensor for the Combustible (LEL) Location
- SR-B04 Replacement Carbon Dioxide (CO2) IR Sensor
- SR-Q07 Replacement Volatile Organic Compounds (VOC) PID Sensor, 10.6 eV
- D4-RHM04 Replacement TwinTox Sensor - Carbon Monoxide (CO) and Hydrogen Sulfide (H2S)
- SR-W04 Replacement Combustible Sensor with Heavy Duty Silicone Filter
- SR-W04-UF Replacement Combustible Sensor without Heavy Duty Silicone Filter
- SR-ER04 Replacement Ethylene Oxide (ETO) Sensor (4-Series)
- SR-H1-1S Replacement Hydrogen Sulfide (H2S) Sensor (one-series)
- SR-M1-1S Replacement Carbon Monoxide (CO) Sensor (one-series)
- SR-NR04 Replacement Nitric Oxide (NO) Sensor (4-Series)
- SR-RR04 Replacement Hydrogen (H2) Sensor (4-Series)
- SR-W04-75 Replacement Combustible (LEL) Sensor, for GasAlertQuattro (Unfiltered)
- SR-X1-1S Replacement Oxygen (O2) Sensor (one-series)
- SR-ZR04 Replacement Hydrogen Cyanide (HCN) Sensor (4-Series)
- SR-X-MC Replacement MICROceL Oxygen (O2) Sensor
- Confined Space Kits
- MC-CK-DL GasAlertMicroClip Deluxe Confined Space Kit
- MC-CK-CC Carrying Case for GasAlertMicroClip - with Foam and Lid Insert
- QT-XWHM-R-Y-NA-CS GasAlertQuattro Confined Space Kit
- QT-CK-DL GasAlertQuattro Deluxe Confined Space Kit
- QT-CK-CC Carrying Case for GasAlertQuattro with Foam Insert
- XT-XWHM-Y-NA-CS GasAlertMax XT II Confined Space Kit
- XT-CK-DL GasAlertMax XT II Deluxe Confined Space Kit
- XT-CK-CC Carrying Case for GasAlertMax XT - with foam insert from XT-CK-DL kit
- M5-CK-DL GasAlertMicro 5 Series Deluxe Confined Space Kit
- M5-CK-CC Carrying Case for GasAlertMicro 5 Series - with Foam and Lid Insert from M5-CK-DL Kit
- HU-CK-DL BW™ Ultra Deluxe Confined Space Kit
- HU-CK-CC Carrying Case for Honeywell BW™ Ultra with Foam and Lid Insert
- QT-XUHM-R-Y-NA-CS GasAlertQuattro Premium Confined Space Kit
- XT-XUHM-Y-NA-CS GasAlertMax XT II Premium Confined Space Kit
- Other BW Products
BW Ultra Portable Multi-Gas Detector with Pump
Item #:
XXYY-BW-Ultra
Brand:
BW Technologies
Share this product:
Extra Detection. Ultra Protection.
At Honeywell, we always put your safety where it should be first. With Honeywell BW™ Ultra, our new portable five-gas detector, you will be able to do the same for your workers. Designed specifically for sampling and monitoring confined spaces, before and after entry, Honeywell BW™ Ultra has enhanced sensor technology, visibility on gas readings, comfort, and connectivity. This makes it the most reliable and user-friendly way to prevent a safety incident.
Extra Gas Detection. Extraordinary.
The Honeywell BW™ Ultra complies with all safety regulations in place by detecting your required gases. Furthermore, it goes the extra mile by offering you the option to choose a fifth sensor from a list of gases for added protection at work.
The Honeywell BW™ Ultra is the first gas detector on the market to feature the 1?Series sensor, with fast response, reliable performance and long life, even in extreme working conditions. That means high accuracy and lower costs.
Features & Benefits
Ultra Easy
- Tamper-proof operation with one button operation
- Intuitive LCD icons for quick decision making
- Easy service and maintenance
Ultra Visibility
- Intuitive large dot matrix display giving clear readings
- Smart Gas layout for clear sensor reading
- Hole Watch Mode for quick decision making
- IntelliFlash™ and also Reverse IntelliFlash™ for clear compliance
Ultra Rugged
- Honeycomb-designed housing for extra ruggedness
- Protection designed in the right place
- Scratch-resistant display protector
Ultra Connected
- Honeywell Connected Worker compatible
- Honeywell TouchConnect™ Technology for activating a feature
- Honeywell SafetySuite for unit configuration and reporting
Ultra Comfortable
- Ergonomically designed for easy use
- Light yet rugged design
- Fits in the hand for easy sampling
Ultra Quick
- Quick responding sensor technology
- Quick decision making because large display
- Quick bump & calibration with IntelliDoX system
SIZE | 5.8 x 3.3 x 1.6 in. / 14.8 x 8.5 x 4.0 cm |
WEIGHT | 14.5 oz. / 411 g (with clip) |
OPERATING TEMPERATURE | -4 to +131° F / -20 to +50° C |
HUMIDITY | 5 - 95% RH (non-condensing) continuous |
INGRESS PROTECTION | IP66/68 |
ALARMS AND TYPE | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit) |
SELF-TEST | Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry). |
TYPICAL BATTERY LIFE | 18 hours (14 hours with PID or IR sensor) @ -4° F / -20° C |
PUMP DRAW | Sample from up to 75 ft. / 22.9 m |
CONNECTED WORKER | • Bluetooth™ Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App • Honeywell TouchConnect™ – Easy ability to enter Bump or Calibration mode or change Set-Points |
EVENT LOGGING | 30 alarm events and 10 bump events |
DATA LOGGING | 45 days based on 8 hour shifts every 15 seconds logging |
USER OPTIONS | • Adjust STEL period (5-15 minutes in 1 minute intervals) • Calibration span levels • Calibration interval • Bump test interval • Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v • LEL and PID correction factors • Calibration due date (1 to 365 days, or set to zero for off) • Individual sensor enable/disable • Latching alarms • Stealth mode • Languages: English, French, German, Portuguese, Spanish, Simplified Chinese and Russian |
WARRANTY | Instrument: 3 years Sensors: 3 years (2 years NH3, 1 year PID and Cl2) Battery: 2 years |
GASES | STANDARD MEASURING RANGE |
RESOLUTION |
OXYGEN (O2) | 0-25% vol. |
0.1% vol. |
COMBUSTIBLE GASES (LEL) | 0-100% LEL |
1% LEL |
COMBUSTIBLE GASES (IR)* | 0-5.00% vol. |
0.01% vol. |
HYDROGEN SULFIDE (H2S) | 0-100 ppm |
1 ppm / 0.1 ppm |
CARBON MONOXIDE (CO) | 0-2,000 ppm |
1 ppm |
CARBON MONOXIDE (LOW H2) (CO-H) | 0-1,000 ppm |
1 ppm |
SULFUR DIOXIDE (SO2) | 0-100 ppm |
0.1 ppm |
HYDROGEN (H2) | 0-2,000 ppm |
5 ppm |
CARBON DIOXIDE (CO2) | 0-50,000 ppm |
100 ppm |
AMMONIA (NH3) | 0-100 ppm |
1 ppm |
VOLATILE ORGANIC COMPOUNDS (VOC) ** | 0-1,000 ppm |
1 ppm |
CHLORINE (CL2) | 0-20 ppm |
0.1 ppm |
NITROGEN DIOXIDE (NO2) | 0-50 ppm |
0.1 ppm |
HYDROGEN CYANIDE (HCN) | 0-100 ppm |
0.1 ppm |
NITROGEN MONOXIDE (NO) | 0-200 ppm |
1 ppm |
* Caution – the LEL IR combustible gas sensor option used in Honeywell BW™ Ultra cannot detect certain combustible gases including hydrogen and acetylene. The application should be reviewed to ensure the Honeywell BW™ Ultra can provide adequate detection. For more information, please contact Honeywell Analytics (www.honeywellanalytics.com). |